Program 70 - Verified Account Code Toll Restriction Assignments - Toshiba DK14 Programming Manual

Strata dk digital business telephone
Table of Contents

Advertisement

System & Station
Program 70 – Verified Account Code Toll Restriction Assignments
Program 70 – Verified Account Code Toll Restriction
Assignments
Processor Type:
Program Type:
Initialized Default:
VAC Digit
VACN
Restrict Code
3-150
DK14, DK40i, all RCTUs and BCUs
System
000 for all VACNs
SELECT = Verified Account Code
Number (VACN)
DATA = VAC Digit Restriction
0 = No Digit Restriction
1 = Digit Restriction
Processor Type
Port Range
DK14
000~009
DK40i
000~027
RCTUA
000~031
RCTUBA/BB
000~079
RCTUC/D
000~239
RCTUE/F
000~335
VAC Restrict
VACN
Code
VAC Restrict Code (00~10)
00 =No Station Toll Restriction
01 =Area Code Toll Restriction
02 =Area Code Toll Restriction and 0 or 1 as 1st (or
2nd digit)
03 =Class 1 T.R.07 = Class 5 T.R.
04 =Class 2 T.R.08 = Class 6 T.R.
Processor Type
B1CU
B2CAU/BU
B3CAU/BU
B5CAU/BU
VAC Digit
VAC Restrict
Restrict Code
Code
Port Range
000~055
000~111
000~191
000~335
VAC Digit
VAC Restrict
VACN
Restrict Code
Code
Strata DK Programming
5/00