Program 12 - System Assignments, Basic Timing - Toshiba DK14 Programming Manual

Strata dk digital business telephone
Table of Contents

Advertisement

System & Station
Program 12 – System Assignments, Basic Timing
Program 12 – System Assignments, Basic Timing
Processor Type:
Program Type:
Initialized Default:
Program
Code
1
Standard Telephone Ring Down Timer (Release 4.0)
Pause Timing
3
(Speed Dial)
4
Flash Timing
Pause After Flash
5
(Voice Path Delay)
7
SLT Toll Restriction DTMF Receiver time after Dial 9
DNIS Ext. Network, External Call Forward, and DISA
8
Disconnect Timer for Loop Start Lines
QRCU3/K4RCU3/RRCS/BRCS DTMF Inter-digital
9
Release Time (Standard Phone)
Program 12 Overview
This program assigns system times for ring down, disconnecting calls, pause times, flash times,
auto attendant, DISA, Call Forward External, and DNIS and DTMF receiving decoding.
Code 1: Standard Telephone Ring Down Timer
This feature is available for Release 4.0 and higher. Code 1 assigns the number of seconds that a
Hotline or Emergency standard telephone waits after going off-hook before automatically ringing
a preassigned directory number. If a valid feature access code or [DN] is dialed prior to the ring
down timer expiration, then ring down does not occur. Ring down applies only to standard
telephone ports, not electronic or digital telephone ports. Ring down destination numbers are
assigned in Program *38.
3-44
DK14, DK40i, all RCTUs and BCUs
Station
Program Timing
Code 1
15 secs.
Code 3
1 min.
Code 4
2 secs.
Code 5
0 secs.
Code 8
1 min.
Code 9
4 secs.
SELECT = 1, 3~5, 8, 9
Enter program code from
the table below.
Function
DATA = Enter ring down time (00~60)
SELECT CODE = Enter the 1 digit code which
corresponds to the time listed in the table below.
For Program Codes 8 and 9, the LCD responds with
LINE TIME =, instead of SELECT CODE =.
Code
XX
XX = 2 digits. 00~60 secs.
1
1.5 sec
2
3.0 sec.
1
0.5 sec.
2
2.0 sec. (Not used in U.S.)
4
0.2 sec.
0
no pause
1
1.5 sec.
2
3.0 sec.
XX
XX = 01~30 sec.
0
no disconnect timer
1
4 min. disconnect
2
10 min. disconnect
3
20 min. disconnect
XX
XX = 01~09 secs.
Required
Time
Code
Strata DK Programming
5/00

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dk40iDk424Dk424i

Table of Contents