Program 45-1 – LCR/Toll Restriction Dial Plan
Processor Type:
Program Type:
Initialized Default:
X
Where:
In NXX and NNX,
X =
N =
NXX =
NNX =
AC =
1+ NNX =
10XXX =
101YXXX/101XXXX =
Y =
Program 45-1 Overview
This program enables you to define a dial plan for the Toll Restriction software to recognize the
typical dialing sequence of long distance/local calls made from the system's home area code, and
to identify area and office codes. The dialing plan defines several components of a telephone
number for long distance calling
Notes
Setting the proper dialing plan in this program is also required for the Least Cost Routing
G
feature to function properly.
Strata DK Programming
5/00
DK14, DK40i, all RCTUs and BCUs
Toll Restriction
Assigns Dial Plan 7 to the system (current North American Numbering Plan)
SELECT = 1
DATA = Plan 1~9
Enter Codes 1~9 to indicate the
dial plan for the system.
Plan
9
(101XXXX)+1+NXX+NXX/NXX
8
(101YXXX)+1+NXX+NXX/NXX
7
(10XXX)+1+NXX+NXX/NXX
6
For UK only.
5
0+ (0+ and universal (Codes 5 and 4) are not used in USA.)
4
Universal (0+ and universal (Codes 5 and 4) are not used in USA.)
3
(10XXX)+1+AC+NXX/NXX
2
(10XXX)+1+AC+NXX/1+NNX
1
(10XXX)+AC+NXX/1+NNX
0~9
2~9
Office code (interchangeable with area and office codes; second digit can be
0~9)
Office code (not interchangeable; second digit cannot be 1 or 0)
Area Code
1 may be dialed before office codes
old 5-digit Carrier Access Codes
new 7-digit Carrier Access Codes
0, 5 or 6
Program 45-1 – LCR/Toll Restriction Dial Plan
Toll Restriction/LCR Dial Plans