Program 15 - Ground/Loop/Tie/Did Line Options - Toshiba DK14 Programming Manual

Strata dk digital business telephone
Table of Contents

Advertisement

Program 15 – Ground/Loop/Tie/DID Line Options
Processor Type:
Program Type:
Initialized Default:
SELECT = Program Code
Press
to advance or
back.
To advance the CO line range, press
located beneath the LCD. Press
lower range.
Processor Type
DK14
DK40i
RCTUA
RCTUBA/BB
RCTUC/D
RCTUE/F
Program
LED On
CPC on AR VM
0
Calls and Voice
Detect
Calls
CO/DID/Tie Line
1
DP
Signal
CO/DID/Tie Dial
2
Pulse Rate
20 PPS
(Pulse per sec.)
3
AR Hold
Detect
Crossbar
4
AR Timing
95 msec.
Tandem CO Line
5
Connection with
Enabled
Station Dropout
Forced Account
7
Enabled
Code
No DTMF
Operation After CO
8
receiver
Line Flash
After Flash
Strata DK Programming
5/00
DK14, DK40i, all RCTUs and BCUs
System
All LEDs are Off
LED Buttons = CO line
to go
Specify CO line by setting LEDs as defined by the
table below. When you are finished, all LEDs with
an "X" should be lit.
for a
CO Line Range
001~004
001~012
001~016
001~048
001~144
001~200
LED Off
01
02
03
04
05
Ignore
DTMF
10 PPS
Ignore
ESS
(electronic)
450 msec.
Not
Enabled
Not
Enabled
DTMF
receiver
After Flash
Program 15 – Ground/Loop/Tie/DID Line Options
Processor Type
CO Line Range
B1CU
001~032
B2CAU/BU
001~120
B3CAU/BU
001~120
B5CAU/BU
001~200
Line
LED
06
07
08
09
10
11
12
13
System & Station
14
15
16
17
18
19
20
3-47