Configuring Ripng Timers - Dell PowerConnect B-RX Configuration Manual

Bigiron rx series configuration guide v02.8.00
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

44
Configuring RIPng
For more information about performing these configuration tasks, refer to
Basic IPv6
By default, RIPng is disabled. To enable RIPng, you must enable it globally on the Brocade device
and also on individual router interfaces.
NOTE
You are required to configure a router ID when running only IPv6 routing protocols.
NOTE
Enabling RIPng globally on the Brocade device does not enable it on individual router interfaces.
To enable RIPng globally, enter the following command.
BigIron RX(config-rip-router)#ipv6 router rip
BigIron RX(config-ripng-router)#
After you enter this command, the Brocade device enters the RIPng configuration level, where you
can access several commands that allow you to configure RIPng.
Syntax: [no] ipv6 router rip
To disable RIPng globally, use the no form of this command.
After enabling RIPng globally, you must enable it on individual router interfaces. You can enable it
on physical as well as virtual routing interfaces. For example, to enable RIPng on Ethernet interface
3/1, enter the following commands.
BigIron RX(config)# interface ethernet 3/1
BigIron RX(config-if-e100-3/1)# ipv6 rip enable
Syntax: [no] ipv6 rip enable
To disable RIPng on an individual router interface, use the no form of this command.

Configuring RIPng timers

Table 184
TABLE 184
Timer
Update
Timeout
Hold-down
Garbage-collection
You can adjust these timers for RIPng. Before doing so, keep the following caveats in mind:
1122
Connectivity".
describes the RIPng timers and provides their defaults.
RIPng timers
Description
Amount of time (in seconds) between RIPng routing updates.
Amount of time (in seconds) after which a route is considered
unreachable.
Amount of time (in seconds) during which information about other
paths is ignored.
Amount of time (in seconds) after which a route is removed from the
routing table.
If you adjust these RIPng timers, Brocade strongly recommends setting the same timer values
for all routers and access servers in the network.
Setting the update timer to a shorter interval can cause the routers to spend excessive time
updating the IPv6 route table.
Chapter 43, "Configuring
Default
30 seconds.
180 seconds.
180 seconds.
120 seconds.
BigIron RX Series Configuration Guide
53-1002253-01

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bigiron rx series

Table of Contents