Display Commands - Dell PowerConnect B-RX Configuration Manual

Bigiron rx series configuration guide v02.8.00
Hide thumbs Also See for PowerConnect B-RX:
Table of Contents

Advertisement

Display Commands

You can use the following show commands to view the results of the monitoring activity. These
show commands display information for all event types in one output.
Displaying internal log messages
Display the contents of the internal log by entering the following command.
BigIron RX# show sysmon logs
INFO:May 13 07:29:54: TM Link Error: LP2/TM2/Link2 -- SNM3/FE3/Link43 (disabled)
INFO:May 13 07:29:33: FE Link Error: SNM3/FE3/Link64 -- LP4/TM1/Link2 (disabled)
Syntax: show sysmon logs
NOTE
The size of the internal log table is 10000 logs.
Clearing internal logs
To clear the internal logs, enter the following command.
BigIron RX# clear sysmon logs
Syntax: clear sysmon logs
Displaying current SYSMON configuration
Enter the show sysmon configuration command to view the current configuration for system
monitoring services. Look for lines similar to the following:
BigIron RX# show sysmon config
--- Event TM Link (Enabled) ---
Threshold: 5 / 10, Log Backoff Number: 1800
Action: SHUTDOWN_LINK
----------------------------------
--- Event TM Clock Sync (Enabled) ---
Threshold: 1 / 10, Log Backoff Number: 1800
Action: SYSLOG
----------------------------------
--- Event TM Reg (Enabled) ---
Threshold: 1 / 10, FAP Shutdown: Allowed
Reg 0440: monitor mask 00fefbff, fap shutdown mask 003e0000, syslog mask 003e0000,
log backoff number 1800
FAP shutdown threshold (non-zero only): bit17-1 bit18-1 bit19-1 bit20-1 bit21-1
Reg 0444: monitor mask 0007f8c7, fap shutdown mask 0007e001, syslog mask 0007e001,
log backoff number 1800
FAP shutdown threshold (non-zero only): bit0-1 bit4-1 bit13-1 bit14-1 bit15-1
bit16-1 bit17-1 bit18-1
Reg b900: monitor mask 00000003, fap shutdown mask 00000000, syslog mask 00000000,
log backoff number 1800
FAP shutdown threshold (non-zero only):
Reg 9880: monitor mask 00000003, fap shutdown mask 00000000, syslog mask 00000000,
log backoff number 1800