Configuring the Syslog service
Example of Syslog messages on a device whose onboard clock is set
The example shows the format of messages on a device whose onboard system clock has been
set. Each time stamp shows the month, the day, and the time of the system clock when the
message was generated. For example, the system time when the most recent message (the one at
the top) was generated was October 15 at 5:38 PM and 3 seconds.
BigIron RX(config)# show log
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Static Log Buffer:
Dec 15 19:04:14:A:Fan 1, fan on right connector, failed
Dec 15 19:00:14:A:Fan 2, fan on left connector, failed
Dynamic Log Buffer (50 entries):
Oct 15 17:38:03:warning:list 101 denied tcp 209.157.22.191(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)
Oct 15 07:03:30:warning:list 101 denied tcp 209.157.22.26(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)
Oct 15 06:58:30:warning:list 101 denied tcp 209.157.22.198(0)(Ethernet 4/18
0010.5a1f.77ed) -> 198.99.4.69(http), 1 event(s)
Example of Syslog messages on a device whose onboard clock is not set
The example shows the format of messages on a device whose onboard system clock is not set.
Each time stamp shows the amount of time the device had been running when the message was
generated. For example, the most recent message, at the top of the list of messages, was
generated when the device had been running for 21 days, seven hours, two minutes, and 40
seconds.
1294
ss – seconds
For example, "Oct 15 17:38:03" means October 15 at 5:38 PM and 3 seconds.
If you have not set the time and date on the onboard system clock, the time stamp shows the
amount of time that has passed since the device was booted, in the following format:
<num>d<num>h<num>m<num>s
where:
<num>d – day
<num>h – hours
<num>m – minutes
<num>s – seconds
For example, "188d1h01m00s" means the device had been running for 188 days, 11 hours,
one minute, and zero seconds when the Syslog entry with this time stamp was generated.
Buffer logging: level ACDMEINW, 38 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
BigIron RX Series Configuration Guide