EPSON EPL-C8000
FIP-1.39 CONTROLLER PWB Firmware Related Error
Step
Check point
Perform the preliminary inspection below.
• Remove all optional electrical unit modules to return the
1
printer to the standard condition.
• Check that all connectors are properly connected to the
CONTROLLER PWB.
Updating the CONTROLLER PWB environment
2
Update the DIMM with the latest program.
l
Does the problem still occur?
FIP-1.40 DIMM (SLOT P) Related Error
Step
Check point
Perform the preliminary inspection below:
• Remove all optional electrical unit modules to return the
1
printer to the standard condition.
• Check that all connectors are properly connected to the
CONTROLLER PWB.
Check: DIMM
Format the DIMM and write the control program to the
DIMM.
2
l
Does the problem still occur?
NOTE: Verify the correct direction for setting the DIMM;
and install it to the socket P until it is locked securely.
Chapter 5
TROUBLESHOOTING
Remedy
Yes
Replace/reinstall the defective part(s).
Replace/reinstall the defective part.
Remedy
Yes
Replace/reinstall the defective part(s).
Replace/reinstall the defective part.
No
Go to Step 2.
Problem solved.
No
Go to Step 2.
Problem solved.
Rev. B
5-54