- Check whether no fuse on PCBs is blown.
- Check whether the user uses the machine properly.

13.1.6 Others

0013-1268
/ / / / iR1018 / iR1018J / / iR1022A / iR1022F / iR1022i / iR1022iF /
If a machine is brought from a cold to warm room, its inside can start to develop condensation, leading to various problems.
a. condensation on the BD sensor is likely to cause problems associated with E100
b. condensation on the dust-proof glass is likely to cause poor image density in sub scanning direction
c. condensation on the contact sensor of the reader unit or on the copyboard glass can cause light images
d. condensation on the pickup or feed guide can cause paper feed problems
If the problem given in d. above has occurred, dry wipe the units in the feed system. Do not open the package containing a drum unit right after it has been brought
in from a cold to warm place to avoid condensation. Be sure to leave it alone for a while (1 to 2 hr), opening it after it has become fully used to the temperature of
the site.