Unit Load Calculation
Unit Load Worksheet
9.
Try to exchange modules between carriers to reduce the unit loads for slots 5
and 6 through 27. (Remember that the 100D, 800 NI-BRI, 400 LS, 400 GS/LS,
800, and 800 GS/LS modules have unit loads of 0.0.) Repeat Steps 1 through 8
to recalculate unit loads for each new configuration.
NOTES:
Empty slots are not permitted between modules.
If the unit load for slots 5 and 6 is less than or equal to 27, power is
sufficient for the carrier.
If the exchange does not reduce the unit load for slots 5 and 6 to 27, install
wall power units for the appropriate number of telephones to reduce the unit
load to 27.