MERLIN LEGENDCommunications System Release 6.1
System Planning 555-661-112
3
Lines/Trunks
Selecting Line/Trunk Options
9.
If available, assign a test telephone number that is used for maintenance
by the service provider. For each 100D module with a PRI service type,
write the test telephone number (up to 12 digits) used for maintenance next
to the module number under the Test Telephone Numbers heading on
Form 3b (page 10).
10.
Under the Timers and Counters heading, do one of the following:
Under the Terminal Equipment Identifier (TEI) heading, do one of the
11.
following:
NOTE:
NOTE:
NOTE:
If the system includes DS1 connectivity, all local offerings of DS1
configurations must be reviewed by Lucent Technologies Sales and Design
Support Center (SDSC) personnel to ensure compatibility. For more
information, see Appendix D, "T1/PRI Review." Also, information required
by the facilities vendor is discussed in Appendix E, DS1 Connectivity
Ordering.
NOTE:
The factory does not assign a test telephone number. You must
assign the same number as that furnished by the PRI service
provider. It must be different from the numbers assigned to other
channels associated with the same B-channel group.
To keep the factory setting, leave the Change to column blank.
To change the factory setting for any timer or counter, write the new
threshold on the appropriate line in the Change to column.
To keep the factory-set TEI, check 0.
To change the factory-set TEI, write a value from 1 to 63 in the
space provided.
Issue 1
August 1998
Page 3-38