Lucent Technologies MERLIN LEGEND Release 6.1 System Planning Manual page 198

Release 6.1
Hide thumbs Also See for MERLIN LEGEND Release 6.1:
Table of Contents

Advertisement

MERLIN LEGENDCommunications System Release 6.1
System Planning 555-661-112
4
Features
Group-Assigned Features
Under the Overflow Threshold Time heading, do one of the following:
12.
13.
Under the Prompt-Based Overflow heading, do one of the following:
14.
Under the Group Type heading, do one of the following:
15.
To specify the number of calls allowed into the group calling queue, under
the Queue Control heading do one of the following:
Proceed to the next section, "System Features."
To keep the factory setting and disable the Overflow Threshold
Time, check the 0 seconds box.
To change the threshold, check the second box and write the
maximum number of seconds (1–900) calls wait in the queue in the
space provided.
To keep the factory setting and disable the Prompt-Based Overflow
feature, check the Disabled box.
To enable Prompt-Based Overflow, check the Enabled box.
To keep the factory setting of no automatic login, check the Auto
Logout box.
To change the factory setting from Auto Logout, do one of the
following:
— Check the Auto Login box to indicate automatic login for an
extension that should never be logged out, such as a data
extension.
— Check the Integrated VMI box to indicate automatic login for
a VMS that requires special signaling for integrated
operation.
— Check the Generic VMI box to indicate automatic login for a
VMS that does not require special signaling.
To keep the factory setting, check the 99 calls box.
To change the threshold, check the second box and write the
number of calls (0–98) in the space provided.
NOTE:
Specifying a Queue Control threshold of 0 indicates that no calls are
allowed into the queue (Queue Control is turned off).
Issue 1
August 1998
Page 4-40