Power Supply Input Voltages

Parameter
110V
220V
Frequency

Power Supply Output Voltages

Param
eter
+12VSTB
+12V

System Environmental Specifications

The following table defines the system level operating and non-operating environmental limits.
Parameter
Operating Temperature
Non-Operating Temperature
Non-Operating Humidity
Acoustic noise
Shock, operating
Shock, unpackaged
Shock, packaged
Vibration, unpackaged
ESD
60

Table 8. CRPS Input Voltage

Min
Rated
90 V
100-127 V
AC
rms
180 V
200-240 V
AC
rms
47 Hz
50/60 Hz

Table 9. CRPS Output Voltage

Min
Nom
+11.40V
+12.000V
+11.40V
+12.000V

Table 10. System Environmental Limits Summary

+10°C to +35°C with the maximum rate of change not to exceed 10°C per hour
-40°C to +70°C
90%, non-condensing at 35°C
Sound power:
- 3.5" HDD SKU: 6.9BA at idle and 7.4BA at active mode;
- 2.5" HDD SKU: 6.5BA at idle and 7.07BA at active mode.
Half sine, 2 g peak, 11 milliseconds
Trapezoidal, 25 g, velocity change 136 inches/second (40 lbs to < 80 lbs)
Non-palletized free fall in height 24 inches (40 lbs to < 80 lbs)
5 Hz to 500 Hz, 2.20 g RMS random
+/-12 KV except I/O port +/- 8 KV per Intel
Max
Start up VAC
140 V
85 V
± 4V
rms
rms
AC
264 V
rms
rms
63 Hz
Ma
Unit
x
+12.60V
Vrms
+12.60V
Vrms
®
Intel
Server System H2000WP Family Service Guide
Power Off VAC
70V
±5V
AC
AC
AC
Tolerance
±5%
±5%
Limits
®
Environmental test specification