Ethernet Connection; Parallel Cable Connection - EFI KM-C1530 Configuration Manual

Ver 2.0
Hide thumbs Also See for KM-C1530:
Table of Contents

Advertisement

1
1-12 Connecting to the Network

Ethernet connection

For Ethernet connections, the Fiery X3e supports cabling, defined as Category 5 for
use with 100BaseT; or as Category 3, Category 4, or Category 5 for use with 10BaseT.
The cable uses an 8-pin RJ-45 connector that plugs into the RJ-45 socket on the
Fiery X3e.
The 100BaseT type supported by the Fiery X3e is 100BaseTX, also known as
N
:
OTE
Fast Ethernet. If an Ethernet hub is used, it must be a 100BaseTX hub. The term
"100BaseT" is used to refer to 100BaseTX.
T
E
O CONNECT TO THE
THERNET BOARD
Connect the network cable to the RJ-45 connector on the back of the Fiery X3e.
You must use a Category 5 unshielded twisted pair cable network cable for 100BaseT.

Parallel cable connection

In addition to receiving print jobs over Ethernet or Token Ring, the Fiery X3e can
accept print jobs from a Windows computer through its high-speed parallel port. This
connection is advantageous for portable computers and for workstations on dedicated
networks using protocols other than AppleTalk, TCP/IP, or IPX.
The parallel port connection can be active at the same time as the network ports.
The parallel port cannot be used to connect the Fiery X3e with
N
:
OTE
Command WorkStation or other Fiery utilities.
T
O USE PARALLEL CABLE
1. With the Fiery X3e and the Windows computer turned off, attach the parallel cable to
the parallel port of the Fiery X3e.
For the location of the parallel port, see the illustration on
2. Connect the other end of the cable to the parallel port on the Windows computer.
3. Turn on the computer and the Fiery X3e.
4. Proceed to Setup.
page
1-10.