Exiting Megaraid Manager - LSI SCSI 320-0 Configuration

Raid controller
Hide thumbs Also See for SCSI 320-0:
Table of Contents

Advertisement

Rebuilding Failed Disk Drives,
Manual Rebuild – Batch Mode
Step
1
Choose Rebuild from the MegaRAID Manager main menu. A device selection window is
displayed showing the devices connected to the current controller. The failed drives have
FAIL indicators.
2
Press the arrow keys to select all drives to be rebuilt. Press the spacebar to select the
selected physical drive for rebuild.
3
After selecting the physical drives, press <F10> and type Yes at the confirmation prompt.
The indicators for the selected drives changes to REBLD. Rebuilding can take some time,
depending on the number of drives you have selected and their capacities.
4
When rebuild is complete, press any key to continue.
Press <Esc> to display the main menu.

Exiting MegaRAID Manager

To exit MegaRAID Manager, press <Esc> from the main menu and choose Yes
at the prompt. A message appears if uninitialized logical drives remain in the
system.
MegaRAID Configuration Software Guide
84