Physical Drive Menu - LSI SCSI 320-0 Configuration

Raid controller
Hide thumbs Also See for SCSI 320-0:
Table of Contents

Advertisement

Physical Drive Menu

The Power Console Plus Physical Drive menu is:
Rebuild
Choose the Rebuild option to rebuild one or more failed disk drives. Follow the
instructions on the screen. Select Abort Rebuild to stop the rebuild process at
any time. The drive will revert to its original status before the rebuild began.
A RAID 1, 3, or 5 configuration has built-in redundancy. If a drive in a RAID
group fails, the RAID subsystem continues to work but no additional
redundancy is provided. Another drive failure will bring the system down. But
the failed drive can be replaced and added into the RAID system by rebuilding
the drive. Select Rebuild to perform this function. The rebuild process can take
place while the RAID system is still running, although performance may be
slightly affected.
Format
Choose this option to low-level format one or more physical drives. A physical
drive can be formatted if it is not part of a configuration and is in a Failed or
Ready state. Since most SCSI drives are factory formatted, you should format a
drive only if the drive:
was not low-level formatted at the factory, or
has an excessive number of media errors.
Do not use Format to erase information or partitions on a SCSI drive. That
information is erased when you initialize the logical drive(s).
Update Drv Firmware This option has not been implemented yet.