Megaraid Configuration On Disk; Configuration Utility Configure Menu - LSI SCSI 320-0 Configuration

Raid controller
Hide thumbs Also See for SCSI 320-0:
Table of Contents

Advertisement

MegaRAID Configuration On Disk

MegaRAID supports Configuration on Disk (drive roaming). Configuration on
Disk saves configuration information both in the MegaRAID NVRAM and on
the disk drives attached to MegaRAID. If MegaRAID is replaced, the new
MegaRAID controller can detect the RAID configuration, maintaining the
integrity of the data on each drive even if the drives have changed channel
and/or target ID.
Note:
It is important that the new controller have no configuration. Make sure that
NVRAM Configuration is cleared before you install SCSI cables.
Adding Configuration on Disk Support Perform the following steps:
Step
1
Press <Ctrl> <M> at the MegaRAID POST screen to run the MegaRAID
Configuration Utility.
2
Select the Configure Menu. Select View/Add Configuration. Select Disk
when asked to use Disk or NVRAM and select Save.
3
Press <Esc> to exit MegaRAID Configuration Utility.
4
Reboot the computer.
Note:
It is important that the new controller have no configuration. Make sure that
NVRAM Configuration is cleared before you install SCSI cables.
Action
Chapter 2 MegaRAID Configuration Utility
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scsi 320-2Megaraid

Table of Contents