Adding Capacity Under Windows Nt 3.5X, 4.X And Windows 2000 - LSI SCSI 320-0 Configuration

Raid controller
Hide thumbs Also See for SCSI 320-0:
Table of Contents

Advertisement

Adding Capacity under Windows NT 3.5x, 4.x and Windows 2000

Adding capacity under NT 3.51 and 4.x You can add capacity or a HDD to an existing array
only under the following conditions:
the Virtual Sizing option is enabled in the "Boot Up Configuration Utility"
the FlexRAID Power Fail Option needs to be enabled
only one logical drive can be configured per array (not per controller)
drives can be added to RAID levels 0, 3, or 5 only
new drive(s) have been added to the SCSI bus or subsystem
Adding capacity under Windows 2000 You can add capacity or a HDD to an existing array only
under the following conditions:
the FlexRAID Power Fail Option needs to be enabled
only one logical drive can be configured per array (not per controller)
drives can be added to RAID levels 0, 3, or 5 only
new drive(s) have been added to the SCSI bus or subsystem
disk cannot be dynamic; this feature supports Basic Disk only
Adding Hard Disk Drives under Power Console
Step
1
On the main menu screen, verify that the drive(s) that were added display on
the appropriate channel.
2
On the Logical Drive tool bar above the channel display, right click on the
Logical Drive icon.
3
From the pull down menu select Advanced Menu, then Add Drive.
4
The Enhanced Logical Drive window appears.
5
Click on the drive(s) you want to add to the existing array.
Note: There is a limit of eight physical drives in an array. Stripe size
cannot be changed, even though it displays on this screen.
6
Select RAID Level from the top part of the screen to change RAID levels.
7
Click on the Apply button and the array will go into a rebuild state.
8
After the rebuild is complete, the additional space must be added to the NT
Disk Administrator.
Action
Chapter 9 Virtual Sizing and Online Capacity Expansion
Cont'd
133