LSI SCSI 320-0 Configuration page 148

Raid controller
Hide thumbs Also See for SCSI 320-0:
Table of Contents

Advertisement

Event types
Physical drive state
Informational
changed
Physical drive state
Warning
changed
Physical drive state
Warning
changed
Physical drive state
Informational
changed
Physical drive state
Error
changed
Physical drive state
Informational
changed
Physical drive state
Informational
changed
Physical drive state
Warning
changed
Physical drive
Warning
format status
Physical drive
Informational
format status
Physical drive error
Warning
or the error
Warning
count differs from
the last check
Informational
Temperature is
Warning
over threshold or
Warning
back to normal
Informational
Fan is not
Warning
operational or its
Warning
status changed
Warning
since last check
Power supply is
Informational
not operational or
Warning
its status changed
Warning
since last check
Warning
Warning
Warning
Warning
Warning
Device slot ID
Warning
number changed
Battery backup
Warning
module/pack
Warning
missing or added
MegaRAID Configuration Software Guide
140
Severity
Level
1.Adapter #: Logical Drive # is Optimal
Adapter #: Logical Drive # is Degraded
Adapter #: Logical Drive # is Offline
2. Physical Drive # is changed to READY
Physical Drive # is changed to FAILED
Physical Drive # is changed to REBUILD
Physical Drive # is changed to Hotspare
Physical Drive # is changed to Absent
Physical Drive # is in Format Progress.
Physical Drive #: Format over
Physical Drive Error:
Media Error Count = # Other Error Count =#
Display the last seven SenseData structure entries.
Each SenseData structure has 14 or 16 bytes.
For SAF-TE-compliant boxes:
Adapter # Channel # Target # [ Fans= #, Power
Supplies= #, Slots= # & Temperature Sensors= # ]:
SAFE-TE Information
Temperature Sensor # is ?? Degree: Out of Range
Temperature Sensor # is Normal
Status of Fan # =0x##: Operational
Status of Fan # =0x##: Malfunctioning
Status of Fan # =0x##: Unknown Status
Status of Fan # =0x##: Status Not Reportable
Status of Power Supply #=0x##: Operational and On
Status of Power Supply #=0x##: Operational and Off
Status of Power Supply #=0x##: Malfunctioning and
Commanded On
Status of Power Supply #=0x##: Malfunctioning and
commanded Off
Status of Power Supply #=0x##: Not Present
Status of Power Supply #=0x##: Present
Status of Power Supply #=0x##: Unknown Status
Status of Power Supply #=0x##: Status Not
Reportable
Device Slot # ID=#:
The associated physical drive ID has changed.
Physical Drive # is Removed/Power Off. Physical
Drive # is Added/Power On.
These messages are not currently available.
Battery Status:
Battery Backup Module is Missing
Battery Backup Module present but Battery Backup
Pack is Missing
Log Messages

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scsi 320-2Megaraid

Table of Contents