LSI SCSI 320-0 Configuration page 83

Raid controller
Hide thumbs Also See for SCSI 320-0:
Table of Contents

Advertisement

Using New Configuration,
Step
8
Set the logical drive size. Move the cursor to Size and press <Enter>. By default, the
logical drive size is set to all available space in the array(s) being associated with the
current logical drive, accounting for the Span setting and for partially used array space. For
example, if the previous logical drive used only a part of the space in an array, the current
logical drive size is set to the remaining space by default.
9
Choose the Advanced menu (see below) to set remaining options.
Stripe size This parameter specifies the size of the segment written to each disk in a RAID
1, 3, 5, 10, 30, or 50 logical drive. You can set the stripe size to 2 KB, 4 KB, 8 KB, 16 KB,
32 KB, 64 KB, or 128 KB. The default stripe size is 64 MB.
A larger stripe size produces better read performance, especially if your computer does
mostly sequential reads. If you are sure that your computer does random reads more often,
select a small stripe size.
Write Policy This parameter specifies the cache write policy. You can set the write policy
to Write-back or Write-through. The default setting is Write-through.
In Write-back caching, the controller sends a data transfer completion signal to the host
when the controller cache has received all the data in a transaction. If WriteBack is enabled
and the system is quickly turned off and then on, MegaRAID may hang when flushing cache
memory. Adapters that contain a battery backup will default to WriteBack caching.
In Write-through caching, the controller sends a data transfer completion signal to the host
when the disk subsystem has received all the data in a transaction. This is the default
setting.
Write-through caching has a data security advantage over write-back caching. Write-back
caching has a performance advantage over write-through caching. You should not use
write-back for any logical drive that is to be used as a Novell NetWare volume.
Read-ahead This parameter specifies that the SCSI read-ahead feature is used for the
logical drive. You can set this parameter to Normal, Read-ahead, or Adaptive. The
default setting is Normal.
Normal specifies that the controller does not use read-ahead for the current logical drive.
This is the default setting.
Read-ahead specifies that the controller uses read-ahead for the current logical drive.
Adaptive specifies that the controller begins using read-ahead if the two most recent disk
accesses occurred in sequential sectors. If all read requests are random, the algorithm
reverts to Normal, however, all requests are still evaluated for possible sequential
operation.
Cache Policy This parameter applies to reads on a specific logical drive. It does not affect
the Read-ahead cache. The default setting is Direct I/O.
Cached I/O specifies that all reads are buffered in cache memory.
Direct I/O specifies that reads are not buffered in cache memory. This is the default setting.
Direct I/O does not override the cache policy settings. Data is transferred to cache and the
host concurrently. If the same data block is read again, it comes from cache memory. Press
<Esc> to exit the Advanced Menu.
10
After the current logical drive is defined, select Accept and press <Enter>. If space remains
in the arrays, the next logical drive to be configured appears. Repeat steps 6 to 9 to
configure another logical drive. If all array space has been used, a list of the existing logical
drives appears. Press any key to continue and respond to the Save prompt.
11
Initialize the logical drives you have just configured. See Initializing Logical Drives on
page 79.
Continued
Action
Chapter 4 MegaRAID Manager
75

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scsi 320-2Megaraid

Table of Contents