Start Disk Group Blink; Start Disk Group Defragment - Dell PowerVault MD3620f Command Line Interface Manual

Powervault modular disk storage arrays
Hide thumbs Also See for PowerVault MD3620f:
Table of Contents

Advertisement

In addition, the database configuration diagnostic test can be started using
the storage management software GUI but cannot be stopped using the
storage management software GUI. If you want to stop a running diagnostic
test, you must use the stop storageArray configDbDiagnostic
command.

Start Disk Group Blink

This command identifies the physical disks that are logically grouped
together to form the specified disk group by blinking the indicator LEDs on
the physical disks. (Use the stop diskGroup blink command to turn off the
indicator LEDs on the physical disks.)
Syntax
start diskGroup [diskGroupNumber] blink
Parameter
Parameter
diskGroup

Start Disk Group Defragment

This command starts a defragment operation on the specified disk group.
NOTE:
Defragmenting a disk group starts a long-running operation that you cannot
stop.
Syntax
start diskGroup [diskGroupNumber] defragment
Parameter
Parameter
diskGroup
294
Script Commands
Description
Number of the disk group to identify. You must
put brackets ([ ]) around the disk group number.
Description
Number of the disk group to defragment. You
must put brackets ([ ]) around the disk group
number.