Dell PowerVault MD3620f Command Line Interface Manual page 245

Powervault modular disk storage arrays
Hide thumbs Also See for PowerVault MD3620f:
Table of Contents

Advertisement

IPv6Priority=[0-7] |
IPv4SubnetMask=(0-255).(0-255).(0-255).(0-255)
|
IPv4VlanId=[1-4094] |
IPv6VlanId=[1-4094] |
maxFramePayload=[frameSize] |
tcpListeningPort=[3260, 49152-65536] |
portSpeed=[(autoNegotiate | 100 | 1000)]
Additional Information
When you use this command, you can specify one or more of the parameters.
You do not need to use all of the parameters. Setting the availability
parameter to serviceMode causes the alternate RAID controller module to
take ownership of all of the virtual disks. The specified RAID controller
module no longer has any virtual disks and refuses to take ownership of any
more virtual disks. Service mode is persistent across reset cycles and power
cycles until the availability parameter is set to online.
Use the show controller NVSRAM command to show the NVSRAM
information. When the duplexMode option is set to TRUE, the selected
Ethernet port is set to full duplex. The default value is half duplex (the
duplexMode parameter is set to FALSE).
To make sure that the IPv4 settings or the IPv6 settings are applied, you must
set these iscsiHostPort options:
enableIPV4=TRUE
enableIPV6=TRUE
The IPv6 address space is 128 bits. It is represented by eight 16-bit
hexadecimal blocks separated by colons. The maxFramePayload option is
shared between IPv4 and IPv6. The payload portion of a standard Ethernet
frame is set to 1500, and a jumbo Ethernet frame is set to 9000. When using
jumbo frames, all of the devices that are in the network path should be
capable of handling the larger frame size.
Options for the Ethernet Port Parameter
Script Commands
245

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault md3600f

Table of Contents