Parameters
Parameter
alarm
autoSupportConfig
cacheBlockSize
cacheFlushStart
cacheFlushStop
252
Script Commands
Description
The setting for the audible alarm. This parameter
has these values:
• enable—The audible alarm is turned on and
sounds if a fault occurs.
• disable—The audible alarm is turned off and
does not sound if a fault occurs.
• mute—The audible alarm is turned off if it is
sounding.
If another fault occurs after you set the audible
alarm to mute, the audible alarm sounds again.
The setting for automatically collecting support
data each time the firmware detects a critical
MEL event. This parameter has these values:
• enable—Turns on the collection of support data
• disable—Turns off the collection of support
data
The cache block size that is used by the RAID
controller module for managing the cache. Valid
values are 4 (4 KB), 8 (8 KB), 16 (16 KB), or 32
(32 KB).
The percentage of unwritten data in the cache
that causes a cache flush. Use integer values from
0 to 100 to define the percentage. The default
value is 80.
The percentage of unwritten data in the cache
that stops a cache flush in progress. Use integer
values from 0 to 100 to define the percentage.
This value must be less than the value of the
cacheFlushStart parameter.