Autoconfigure Storagearray Hotspares; Check Remote Replication Status - Dell PowerVault MD3620f Command Line Interface Manual

Powervault modular disk storage arrays
Hide thumbs Also See for PowerVault MD3620f:
Table of Contents

Advertisement

Autoconfigure Storage Array Hot Spares
This command automatically defines and configures the hot spares in a
storage array. You can run this command at any time. This command provides
the best hot spare coverage for a storage array.
Syntax

autoConfigure storageArray hotSpares

Parameters
None.
NOTE:
When you run the autoconfigure storageArray hotSpares command, the
RAID controller module firmware determines the number of hot spares to create
based on the total number and type of physical disks in the storage array.

Check Remote Replication Status

NOTE:
This command valid only with Fibre Channel storage arrays.
This command returns the status of a remote replication virtual disk. Use this
command to determine when the status of the remote replication virtual disk
becomes Optimal.
Syntax
check remoteReplication localVirtualDisk
[virtualDiskName]
optimalStatus timeout=timeoutValue
Parameters
Parameter
localVirtualDisk
Description
The name of any remote replication virtual disk. The
remote replication virtual disk can be the primary virtual
disk or the secondary virtual disk of a remote replication
pair. Enclose the virtual disk name in square brackets ([ ]).
If the virtual disk name has special characters, you also
must enclose the virtual disk name in double quotation
marks (" ").
Script Commands
147

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault md3600f

Table of Contents