Start Physical Disk Channel Fault Isolation Diagnostics

This command runs the physical disk channel fault isolation diagnostics and
stores the results.
Syntax
start physicalDiskChannel [(1 | 2 )]
controller [(0 | 1)] faultDiagnostics
testDevices=[(all | controller=(0 | 1) |
emms=[enclosureID1 (left | right), enclosureID2
(left | right)... enclosureIDn (left |right)] |
physicalDisks= (enclosureID1,slotID1 ...
enclosureIDn,slotIDn)] | (dataPattern=(fixed |
pseudoRandom) |
patternNumber=[(0xhexadecimal | number)] |
maxErrorCount=integer | testIterations=integer |
timeout=timeInterval)
Parameters
Parameter
physicalDiskChannel The identifier number of the physical disk channel that
controller
testDevices
dataPattern
Description
you want to locate. Valid values for the identifier
number are 1 or 2. Enclose the identifier number in
square brackets ([ ]).
The identifier letter of the RAID controller module that
you want to test. Valid RAID controller module
identifier values are 0 or 1, where, 0 is the RAID
controller module on the left, and 1 is the RAID
controller module on the right when viewed from the
rear of the enclosure.
The identifiers of the devices (RAID controller
modules, EMMs, or physical disks) that you want to
test. You can specify all or enter the specific identifiers
for the devices that you want to diagnose.
The method of repeatability that you want to test.