Dell PowerVault MD3620f Command Line Interface Manual page 253

Powervault modular disk storage arrays
Hide thumbs Also See for PowerVault MD3620f:
Table of Contents

Advertisement

Parameter
defaultHostType
failoverAlertDelay
mediaScanRate
password
userLabel
isnsRegistration
Additional Information
When you use this command, you can specify one or more of the
optional parameters.
Auto Support Data
When enabled, the set storageArray autoSupportConfig command causes all
configuration and state information for the storage array to be returned each
time a critical Major Event Log (MEL) event is detected. The configuration
Description
The default host type of any unconfigured host
port to which the RAID controller modules are
connected. To generate a list of valid host types
for the storage array, run the show storageArray
hostTypeTable command. Host types are
identified by a name or a numerical index.
Enclose the host type name in double quotation
marks (" "). Do not enclose the host type
numerical identifier in double quotation marks.
The failover alert delay time in minutes. The
valid values for the delay time are 0 to 60
minutes. The default value is 5.
The number of days over which the media scan
runs. Valid values are disabled, which turns off
the media scan, or 1 day to 30 days, where 1 day is
the fastest scan rate, and 30 days is the slowest
scan rate. A value other than disabled or 1 to 30
does not allow the media scan to function.
The password for the storage array. Enclose the
password in double quotation marks (" ").
The name for the storage array. Enclose the storage
array name in double quotation marks (" ").
The method to register the iSCSI target with the
iSNS server. Set the parameter to TRUE to
enable registration. Set the parameter to FALSE
to disable registration.
Script Commands
253

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Powervault md3600f

Table of Contents