If there is a host with a restricted host type that is part of a specific storage
partition, all of the hosts in that storage partition are limited to the
maximum number of LUNs allowed by the restricted host type.
You cannot move a host with a restricted host type into a storage partition
that already has LUNs mapped that are greater than what is allowed by the
restricted host type. For example, if you have a restricted host type that
allows only LUNs up to 31, you cannot move that restricted host type into
a storage partition that has LUNs greater than 31 already mapped.
The Default Group on the Mappings tab has a default host type. You can
change this type by selecting Storage Array Change Default Host Type.
If you set the default host type to a host type that is restricted, the maximum
number of LUNs allowed in the Default Group for any host is restricted to
the limit imposed by the restricted host type. If a particular host with a non-
restricted host type becomes part of a specific storage partition, you can
change the mapping to a higher LUN.
Changing the RAID Controller Module Ownership of a Virtual Disk or a
Disk Group
You can change the RAID controller module ownership of a virtual disk or a
disk group.
You can change the RAID controller module ownership of a standard virtual
disk or a snapshot repository virtual disk. You cannot directly change the
RAID controller module ownership of a snapshot virtual disk because the
snapshot virtual disk inherits the RAID controller module owner of its
associated source virtual disk. Changing the RAID controller module
ownership of a virtual disk changes the preferred RAID controller module
ownership of the virtual disk.
During a virtual disk copy, the same RAID controller module must own both
the source virtual disk and the target virtual disk. Sometimes both virtual
disks do not have the same preferred RAID controller module when the
virtual disk copy starts. Therefore, the ownership of the target virtual disk is
automatically transferred to the preferred RAID controller module of the
source virtual disk. When the virtual disk copy is completed or is stopped,
ownership of the target virtual disk is restored to its preferred RAID controller
module. If ownership of the source virtual disk is changed during the virtual
144