Set Storage Array Redundancy Mode

This command sets the redundancy mode of the storage array to either
simplex or duplex.
Syntax
set storageArray redundancyMode=(simplex | duplex)
Parameter
Parameter
redundancyMode
Set Storage Array Security Key
Use this command to set the security key that is used throughout the storage
array to implement the Physical Disk Security premium feature. When any
security-capable physical disk in the storage array is assigned to a secured disk
group, that physical disk is security-enabled using the security key. Before you
can set the security key, you must use the create storageArray securityKey
command to create the security key.
Syntax

set storageArray securityKey

Parameters
None.
Additional Information
Security-capable physical disks have hardware to accelerate cryptographic
processing and each has a unique physical disk key. A security-capable
physical disk behaves like any other physical disk until it is added to a secured
disk group. When a security-capable physical disk is added to a secured disk
group, it becomes security-enabled.