Modular Alarm Platform 5000
Internal program
Points of the point type Intrusion can be assigned to an internal program.
When points are assigned to an internal program, and internal program is switched on, the
points are capable of alarm signaling in disarmed state.
If the detector is tripped, an internal alarm is generated.
This internal alarm results in only local alarm signaling without a remote alarm.
Outputs for individual applications
Outputs of the MAP5000 panel can be used to control individual applications. A prerequisite
for this is that no behavior item (no activation by the intended operation of the panel) is
assigned to such an output.
Manual output control
4
Automatic via schedule
1.
2.
3.
Chime mode
If Chime Mode is activated on the touch keypad in disarmed state, tripping of an intrusion
point with the option Chime Mode Capable leads to a one-off chime tone on the touch
keypad.
4
9.3

Requirements in accordance with SES

The basis for this requirement is the standard EN 50131 grade 3 (refer to Requirements in
accordance with EN 50131 grade 3, page 80). Deviations from this standard are already taken
into account in the fundamental behavior of the MAP5000 panel and / or described below.
9.3.1

Selecting the default setting

1.
2.
Refer to
9.3.2

Automatic arming / disarming

Arming without a warning signal is permitted if it is possible to ensure by technical or
organizational measures that there are no persons in the supervised area before arming.
Automatic arming at a predefined time with warning signal
1.
2.
3.
4.
Bosch Security Systems B.V.
Select Touch Keypad > Behavior >Outputs Available For Direct Command.
Using the schedule wizard, enter the time when the output is to be switched on/off.
As action, select Output ON or Output OFF.
The schedule can optionally be edited at the touch keypad. Schedule > Behavior > May
Be Edited At Touch Keypad.
Assign the point to the local area of the touch keypad.
Select EN50131 grade 3 as the default property values setting (refer to Standard-
compliant programming, page 65).
If the MAP5000 panel validation in accordance with EN 50131 grade 3 fails, do not
proceed with programming the MAP5000 panel.
Point types and point evaluation, page 67
Standard-compliant programming, page 65
Refer to Automatic arming / disarming, page 82.
Start the schedule wizard and define the time of arming.
As action, select Arm Area(s) Using Exit Delay.
Program the duration of the acoustic warning signal before arming in the area: Area
Manager > Area > Exit Delay > Normal Delay Time.
Deactivate the option Arm Only If Area Is Ready To Arm.
Installation manual