Modular Alarm Platform 5000
Programming two outputs for signaling the armed / disarmed state
1.
2.
3.
Automatic arming at a predefined time: defining the arming time
1.
2.
3.
4.
Automatic bypassing of points can be optionally programmed. For requirements, refer to
Forced Arming with automatic bypass, page 82.
Automatic arming after disarming
4
Automatic disarming at a predefined time: defining the disarming time
1.
2.
Refer to
–
9.2.7
Alarm output via siren and communicator
Alarms, trouble events and other events must be output via siren and/or communicator.
4
External alarm via siren
4
–
–
4
Additional behavior items can be optionally added.
Remote alarm via communicator
4
–
–
–
–
–
Additional reportable events can be optionally added.
Bosch Security Systems B.V.
Connect one free output in each case with the device LED.
Using the wizard, program one output with the behavior item Area Armed and a second
output with the behavior item Area Disarmed.
The signal must be time-limited. Enter a corresponding time (defaulted 10 seconds /
maximum of 30 seconds) for Activation Duration.
Start the schedule wizard and define the time of arming.
As action, select Arm Area(s) Using Exit Delay.
Program the duration of the acoustic warning signal before arming in the area: Area
Manager > Area > Exit Delay > Normal Delay Time.
The option Arm Only If Area Is Ready To Arm must be deactivated.
Do not set the option Automatic Arming after Disarming for an area. The procedure
does not comply with the requirements of EN 50131.
Start the schedule wizard and define the time of disarming.
As action, select Disarm Area(s).
Forced Arming with automatic bypass, page 82
For possible variants, refer to Sirens and communicator in accordance with EN50131
grade 3, page 70.
Activate the sirens at least for the following events (behavior items):
External intrusion alarm
External tamper alarm
Set the option Panel Wide Device.
Activate the communicator at least for the following events (Event Manager > Panel
Event Groups > Properties > Reportable Events):
External intrusion alarm
External tamper alarm
Hold-up alarm
Duress alarm
Summary trouble
Installation manual
Appendices | en
2024-10 | V26 | F.01U.168.332
83