Real-Time Parallel Output Unit - Omron ZS-HL User Manual

Smart sensor 2d cmos laser type
Hide thumbs Also See for ZS-HL:
Table of Contents

Advertisement

Real-Time Parallel Output Unit

ZS-RPD11/RPD41
(14.15)
13
30
Item
I/O type
NPN Amplifier Unit
Data output system
16-bit parallel open collector output
Data format
Measurement value data is converted to 40,000 stages of 16-bit binary data before
output. (signal names: D0 to D15)
Data update cycle
Can be set as desired using integer multiples of the sampling cycle. The update cycle
is determined by the following calculation formula:
• (update cycle) = (sampling cycle) × (update coefficient)
The update coefficient parameter can be set by the user as an integer value within the
range 1 to 100. (Ex. When the sampling cycle is 112 µs, the settable range becomes
112 µs to 11.2 ms.)
Synchronization signal Synchronization signal for notifying data determination timing (signal name: GATE).
1-bit open collector output
Signal name
• Binary output: signal name: D0 to D15 (total 16 bits)
• Gate output: signal name: GATE (total 16 bits)
Circuit specifica-
NPN open-collector,
tion
30 VDC max., 50 mA max.,
residual voltage 1.2 or less
delay time at OFF → ON change: less
than 0.5 µs
(at 24 V, 20 mA)
RS-232C
1 port, max. 115,200 bps
• PWR indicator (lit color: green) → Lit when ZS-RPD is energized.
Status indicators
• ERR indicator (lit color: red) → Lit when an energizing current of 20 mA or more flows
to 1 bit or more of the open collector output (data output: 16 bits, GATE: 1 bit)
Circuit internal power
24 VDC and 3.3 VDC. Power supplied form ZS-HLDC_1 via exclusive connector.
supply voltage
Current consumption
0.5 A or less. Total value including current consumption of ZS-HLDC_1
Insulation resistance
Connected to ZS-HLDC_1, across all lead wires and controller case of the ZS-
HLDC_1: 20 M
Dialectic strength
Connected to ZS-HLDC_1, across all lead wires and controller case of the ZS-
HLDC_1: 1000 VAC, 50/60Hz 1min
10
28.40
29.60
15.85
66.50
9
80
89
98
(2.85)
70
35.20
ZS-RPD11
(by 250 V megger)
2 mm mounting hole
15.65
9
(150)
ZS-RPD41
PNP Amplifier Unit
PNP open-collector,
20 mA max., residual voltage 1.2 V or
less,
delay time at OFF → ON change: less
than 0.5 µs
(at 20 mA)
delay
Section8
Accessory
(Unit: mm)
delay
ZS-HL
8-47
User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents