Measuring Height (basic)

Measuring Height (basic)
This section describes the basic setting procedures for measuring height.
Setting for sensing conditions
1.
Set the mode switch to FUN.
2.
Select
[SENSING]-[MODE].
[HI-RESO]: Usually select this menu. A stable measurement can be performed
[HI-SENS]: In addition to the effect of [HI-RESO], a measurement is stable even
3.
Select the mounting status of the
Head in [SENSING]-[SETTING].
4.
Select the material of the work-
piece in [SENSING]-[OBJECT].
[NORMAL]: Usually select this menu.
[PCB]
[MIRROR] : For a mirror
[GLASS] : For glass
ZS-HL
3-2
User's Manual
Sensor head
height
measurement
mode
while the effect of the front side of the workpiece is minimized.
when the received light amount is insufficient. (black rubber, PCB, etc.)
: When a laser beam passes through an object like PCB and there is a
diffused reflection effect.
Name of the Controller and Key Code
LD ON ZERO ENABLE
H
Main display
P
L
Sub-display
1
3
H
L
FUN
RUN
TEACH
in
1
STAND
3
H-SPEED
1
DIFFUSE
1
NORMAL
3
MIRROR
ESC
MENU
2
4
FUN
RUN
SET
TEACH
2
HI-RESO
2
REGULAR
2
PCB