Usb Rs-232C - Omron ZS-HL User Manual

Smart sensor 2d cmos laser type
Hide thumbs Also See for ZS-HL:
Table of Contents

Advertisement

RS-232C
Connections to the programmable controller, programmable terminal, and personal
computer can be made.
Communication can be performed using non-procedural or CompoWay/F commands.
For details on formats for non-procedural and CompoWay/F commands, refer to the
"Communication Command Reference" (provided separately).
Obtaining a measurement result
Using NS SmartMonitor, the settings can be changed from the programmable terminal and
the measurement can be monitored on the programmable terminal.
Settings for RS-232C Connection p.7-5
Two lines from the USB port and RS-232C connector can be used together for communication. For
example, "data confirmation/analysis" and "data collection/control, change of device setup" can be per-
formed simultaneously.
Control by CompoWay/F
communication
[Data confirmation/analysis]
• Check the SENSING screen
• Check the measured value
• Perform logging for the measured
value
Personal computer
Note that there are restrictions as described below for communication in which two lines are used
together.
• The command entered first becomes valid, and the command entered next is executed after process-
ing of the first command ends.
• There are restrictions for commands that are allowed to be entered simultaneously from RS-232C and
USB. For details, refer to the "Communication Command Reference" (provided separately).
Command communication
Bank switching
Zero reset
RS-232C cable ZS-XPT2
Setting
Measured value
RS-232C cable ZS-XPT2
USB
Programmable controller
Programmable terminal
Control by non-procedural communication
[Data collection/control, change of
device setup]
• Obtain the measurement result
• Execute zero reset
• Switch bank
RS-232C
Programmable controller
Section7
Overview
ZS-HL
7-3
User's Manual

Hide quick links: