Search from Menu Tree

■ FUN Mode
● For the Single-Task mode
FUN Mode
ZS-HL
16
User's Manual
SENSING
FILTER
OUTPUT
HOLD
Zero reset
Settings
MODE
STAND, HI-RESO
SENS
CUSTOM (EXPOSE, SKIP,
LINE)
*
GAIN
1
, 2, 3, 4, 5
SETTING
DIFFUSE, REGULAR
LASER
*
AUTO
, RANGE, FIXED
(upper limit 0.1 to 80 %)
OBJECT
NORMAL
GLASS (MODE 1, MODE2),
THICK (MODE 1, MODE2)
*
SYNC
OFF
,
ON (timing A, timing B)
SMOOTH
*
OFF, ON
AVERAGE
1, 2, 4, 8, 16, 32, 64, 128
1024, 2048, 4096
(When the mode is set to HIGH-
SPEED mode, the value is from 1 to
256.)
DIFF
*
OFF
, ON
SCALING
*
OFF
, ON (AUTO, MAN)
TYPE
*
OFF
, PEAK, BOTTOM,
P-P, AVERAGE,
SAMPLE
TRIGGER
EXT
*
, SELF-UP, SELF-DN
DELAY
*
OFF
, ON (T-DELAY, T-TIME)
TYPE
*
REAL
, HOLD
OFFSET
-999.999 to 999.999 (default value:0)
*
STATUS
OFF, ON
*Default Value
Option/Range
Pages
*
, HI-SPEED, HI-
p.5-6
p.5-7
p.5-8
p.5-8
*
, PCB, MIRROR,
p.5-9
p.5-11
p.5-12
*
, 256, 512,
p.5-13
p.5-13
p.5-14
p.5-18
p.5-22