5.
Set point 2 in the same way as point 1.
If the points are not set correctly, check the following:
• Is the measured value set on the sub-display within the measuring range
(with scaling and calculation settings reflected if set)?
• Are the first and second measured points separated by at least 1 % of the rated measuring
range?
• Are the current (or voltage) values for the two points the same?

Correcting Linear Output Values

Discrepancies may occur between the linear output current (or voltage) values set on the
Sensor Controller and the actual current (or voltage) values measured due to the
conditions for the connected external device or other factors. The linear output correction
function can be used to correct this discrepancy.
The output values are corrected by entering the correction value for the current (or
voltage) values for any two points. (default value: OFF)
Range: -999 to 999
Set the focus function and select either current or voltage output beforehand. Also, connect the linear
output to an external ammeter or voltmeter.
FUN mode-[I/O SET]-[ANALOG]-[ADJUST]-[ON]
1.
Set the output value of point 1.
The output value is displayed on the main
display.
2.
Press the SET Key to apply the setting.
Section6
Settings for Linear Output
INPUT POINT 2
DIG
VAL SET:OK
INPUT POINT 1
CHANGE SET:OK
User's Manual