Setting The Zero Reset Function - Omron ZS-HL User Manual

Smart sensor 2d cmos laser type
Hide thumbs Also See for ZS-HL:
Table of Contents

Advertisement

Section5
Setting Output Processing of Sensing Information

Setting the Zero Reset Function

■ TYPE
Set how zero reset is to be executed.
FUN Mode-[OUTPUT]-[0RESET]-[TYPE]
REAL
HOLD
■ OFFSET
Set an offset to set the reference value for zero reset to a value other than 0.
FUN mode-[OUTPUT]-[0RESET]-[OFFSET]
OFFSET
■ STATUS
Set valid/invalid for the zero reset function.
FUN mode-[OUTPUT]-[0RESET]-[STATUS]
ON
OFF
In Multi-Task mode, set ON/OFF for each TASK.
ZS-HL
5-22
User's Manual
Setting
Sets the measured value when a zero reset is executed to zero. (default value)
Sets the measured value (hold value) when a zero reset is executed to zero.
This setting is enabled when hold measurement is performed.
Setting
Sets the reference value.
Range: -999.999 to 999.999 (default value: 0)
Setting
When a zero reset input is received externally, a zero reset is executed.
(Default Value)
Even when a zero reset input is received externally, a zero reset is not exe-
cuted.
Description
Measurement of height
from reference surface
Zero reset
Reference A
Hold A
(reference)
Zero reset
Direction of movement
Description
Description
Measurement of height
from reference surface