Setting the Filter Function
Set the conditions for filtering information obtained from the sensor.
Displacement
Waveform
when filter
function is not
Smooth
set
SMOOTH
Average
value
Displacement
Differentiation
0
Setting SMOOTH
The intermediate value of multiple sets of data can be output as the measurement result.
This function removes any abnormal values such as spiking that occur when the shape of
the workpiece suddenly changes during measurement.
Example: To remove spiking
Abnormal values such as spiking that occur when the shape
of the workpiece suddenly changes during measurement.
The smoothing function can remove spikes
FUN Mode-[FILTER]-[SMOOTH]
Setting
OFF
The smooth function is not used.
ON
The intermediate value of the past 15 measured values is set as the measurement
result at each sampling cycle.(default value)
When "HI-SPEED" is set in the measurement mode, [OFF] is set.
Supplementary Explanation
Helpful information regarding operation and reference
pages are introduced here using symbols.
Section5
Setting the Filter Function
Spike-like changes are
removed.
Changes are smoothed out.
Changes are extracted to
eliminate displacement value.
Time
Time
Description
ZS-HL
User's Manual
*This page has been made purely for explanatory purposes and does not exist.
Precautions for Correct Use
Title of each section
Header
Overview
Cross-header
Overview of the
cross-header
Index label
Indicates the section
number and title.
Movement through menus
up to setting items
Explanation of options
5-11
Introduction
ZS-HL
9
User's Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents