Omron ZS-HL User Manual page 70

Smart sensor 2d cmos laser type
Hide thumbs Also See for ZS-HL:
Table of Contents

Advertisement

Section4
Threshold Setting
■ TEACHING
Performs measurement and uses the measurement results to set threshold values.
Teaching is useful when threshold samples, i.e., with the upper and lower limits, can be
obtained beforehand.
Sensor Head
Threshold sample (upper limit)
Hold, trigger, and scaling settings that have been made before teaching are reflected in
the teaching measurements.
The following describes the operation method using the procedure for setting the HIGH
threshold value as an example.
1.
Set the mode switch to TEACH.
2.
Switch the threshold switch to "H" to
set the HIGH threshold value.
3.
Set the workpiece.
4.
Press the MENU key to apply the set-
ting.
The applied threshold value will be
displayed on the sub-display.
ZS-HL
4-8
User's Manual
Teaching point
= HIGH threshold value
Threshold sample (lower limit)
Sensor Head
Teaching point
= LOW threshold value
FUN
ESC
MENU
1
2
3
4
TEACH
SET
H
L
FUN
RUN
ESC
MENU
1
2
3
4
TEACH
SET
H
L
FUN
RUN
TEACHMODE
MENU: TEACHING
TEACH
RUN
H
L