Setting Measurement Object

Set the type of workpiece to be measured.
In Multi-Task mode, [THICK] is not displayed.
FUN Mode-[SENSING]-[OBJECT]
Setting
STAND
PCB
MIRROR
Glass
Mode1
Mode2
Usually, select this setting. (default value)
Select this setting for workpieces such as PCBs through which light penetrates.
Select this setting for workpieces having a mirror surface.
Select this mode to measure glass at high speed.
(This is not displayed in Multi-Task mode.)
Select this mode when you want to measure glass stably.
This is effective when measuring the thickness of glass having different reflection
factors on the front side
and the backside
(This is not displayed in Multi-Task mode.)
Front side
Backside
When MODE2 is selected, two areas are measured and the measured value that is
closer to the Sensor Head is output as the result of the front side of the glass.
When MODE2 is selected, the measurement area is set for the front side and back-
side of the glass respectively, and an adjustment is performed for a suitable
received light amount for each area.
Mode 1
When you use SmartMonitor ZS, you can adjust the area while checking the
received light amount.
Setting for Sensing Conditions
Description
Glass
such as backside deposited glass.
Glass with a film
For example, backside
deposited glass.
Mode 2
Automatically
adjusts the
received light
amount.
Area of the front side
Received light amount of the front side
Received light amount of the backside
Area of the backside