■ DELAY
A delay time is set to ignore measured values immediately after the timing input. This is
useful for avoiding bounding during device startup and the influence of machine vibra-
tion.
The delay time (the delay between timing input and the start of sampling) and the sam-
pling period can be set.
Timing input
FUN mode-[OUTPUT]-[HOLD]-[DELAY]
Setting
OFF
ON
Setting Output Processing of Sensing Information
Delay time
Sampling period
ON
OFF
Ignored
The delay time is not set. (default value)
Sets the delay time.
When ON is selected, the following items are subsequently displayed:
• T-DELAY
Sets the delay time.
Range: 0 to 9000 (ms)
• T-TIME
Sets the sampling period.
Range: 1 to 9000 (ms)
Set so that the "delay time + sampling period" is less than the timing
input ON interval. If the next timing input for measurement is received
before the "delay time + sampling period" has elapsed, that timing
input will be ignored and will not be reflected in the sampling.
Delay time
Accepted