Section6
Timing Charts
■ Bank Switching
BANK input
Internal processing
BUSY output
Judgment output
T14 Time of receiving bank
switching input
T15 Bank switching time
T16 Time after the end of bank
switching until the output of
valid data
■ Laser OFF
Laser OFF input
Internal processing
Laser beam emission
Judgment output
T4
Time of receiving laser OFF
input
T5
Response time of laser
OFF input
T17 Time after the canceling of
laser OFF input until the
output of valid data
ZS-HL
6-22
User's Manual
T14
OFF
ON
Item
Minimum
Sampling
cycle × 3
It changes according to the measurement conditions
• When the parameters from (1) to (3) are the same between BANKs:
Within 1s
• When the parameter of (1) is in a mode other than High-Speed mode
and the parameter of (3) is the same between BANKs: Within 3s
• Other cases: Within 15s
(*1) Measurement conditions
(1) Measurement mode (STAND/HI-SPEED/HI-RESO/HI-SENS/CUS-
(2) Scaling
(3) Sensor installation (Regular reflection/diffuse reflection)
Sampling
cycle × aver-
age number
OFF
ON
T5
ON
OFF
Item
Minimum
500 ms
Sampling
cycle × aver-
age number
T15
T16
Average
Maximum
Sampling
cycle × 4
TOM)
Sampling
cycle × (15 +
average num-
ber)
T4
T5
CLAMP output or KEEP output
Average
Maximum
500ms
Sampling
cycle × (15 +
average num-
ber)
Remarks
as follows:
(*1)
Time when the adjust-
ment of light amount is
"automatic".
T17
Remarks
It is the time for adjust-
ment of the light
amount and average
number of buffers.