Omron ZS-HL User Manual page 91

Smart sensor 2d cmos laser type
Hide thumbs Also See for ZS-HL:
Table of Contents

Advertisement

FUN Mode-[OUTPUT]-[SCALING]-[ON]-[AUTO]
1.
Set the first point by following steps 1 to 4 of
the one-point scaling procedure.
2.
Place the sensing object at the position (sec-
ond point) to perform scaling, and enter the
desired offset value (second point).
Press the LEFT key. The sub-display blinks.
3.
Press the SET Key to apply the setting.
■ Manual Setting
Enter numerical values for scaling correction values.
FUN Mode-[OUTPUT]-[SCALING]-[ON]-[MANUAL]
Setting
SPAN
OFFSET
Setting Output Processing of Sensing Information
Sets the inclination of the sensor characters as a coefficient.
Range: -2.0 to 2.0
Measurement value
(mm)
2.0
-2.0
Adds/subtracts a fixed value to or from the measured value.
Range: -999.99 to 999.999
Measurement value
(mm)
INPUT POINT 1
DIG
VAL SET:OK
INPUT POINT 2
DIG
VAL SET:OK
Description
Workpiece
displacement
Workpiece
displacement
Section5
ZS-HL
5-17
User's Manual