Omron ZS-HL User Manual page 93

Smart sensor 2d cmos laser type
Hide thumbs Also See for ZS-HL:
Table of Contents

Advertisement

Setting
SAMPLE
■ Triggers
Set the input method for the timing of the start and end of the measurement period.
FUN mode-[OUTPUT]-[HOLD]-[TRIGGER]
Setting
EXT
SELF-UP
Setting Output Processing of Sensing Information
Holds the measured value at the start of the sampling period. The output
changes at the start of the sampling period and is held until the start of the
next sampling period.
Current
measured value
Enters the trigger for the start of sampling by using the timing input. The period
that the timing signal is ON is the sampling period.
(default value)
ON
Timing input
OFF
When a delay time is set, the input OFF timing and the end of the
sampling period will not be synchronous. Sampling will end after the
specified sampling period has elapsed.
The sampling period is the period at which the measured value is greater than
the specified self-trigger level. Hold measurement is possible without a sync
input.
Self-trigger level
Measured
value
Sampling period
When SELF-UP is selected, the following items are subsequently displayed:
• TRG LEVEL
Sets the desired self-trigger level.
Range: -999.99 to 999.999
• TRG HYS
Sets the hysteresis width for the self-trigger.
Range: 0 to 999.999
When a delay time is set, the timing when the measured value
becomes smaller than the self-trigger level and the end of the sam-
pling period will not be synchronous. Sampling will end after the spec-
ified sampling period has elapsed.
Description
Sampling period
Description
Sampling period
Sampling period
Section5
Output
Hysteresis width
(for self-trigger)
Action point
Return point
ZS-HL
5-19
User's Manual