Section 5

Linear Output

Linear Output
Output Settings (Monitor Focus)
"Linear output" refers to the conversion of measurement results to a 3 to 21 mA current
output range or a -5 to +5 V voltage output range. The relationship between displayed
measured values and output values can be set freely. Match the settings to suit the
connected external device.
Enter the output values for any two current values or voltage values to set the output
range.
Example: Setting 5 kV to 4 mA output and 15 kV to 20 mA output (for current output)
Output current
(mA)
20
4
0
Allow at least 1 kV between the two points to specify.
The threshold values are cleared when the monitor focus is set. Reset the threshold values after
setting the monitor focus.
ZJ-SD
70
User's Manual
Measured value
20
(kV)
Threshold p.36
Output current
(mA)
20
4
0
Measured value
5
15
(kV)