Table 26: Extended Output Signal Selection - YASKAWA XTRAWARE - V3.0 Manual

Supporting xtradrive versions 3.04 - 3.23
Table of Contents

Advertisement

Note:
When working in YASKAWA Option Board Mode, all input and
output assignments are available. When working in modes C
and D, consult Table 27: Input and Output Availability per
Mode for a list of input and output signals that can be
assigned.
8.8.
Table 26: Extended Output Signal
Selection
The outputs listed in the table below are used in the user program.

Table 26: Extended Output Signal Selection

Parameter
Digit
Place
Pn2D2
0
1
2
3
Notes:
1. When more than one signal is allocated to the same output
circuit, data is output using OR logic.
2. Depending on the control mode, undetected signals are
treated as OFF. For example, in the speed control mode, the
/COIN signal is treated as OFF.
3. Types of /WARN signals: Overload and regenerative
overload.
4. When working in YASKAWA Option Board Mode, all input
and output assignments are available. When working in modes
C and D, consult Table 27: Input and Output Availability per
Mode for a list of input and output signals that can be
assigned.
XtraWare User Manual
Name
Settin
g
QUICK_OUTPUT
0
Signal Mapping
1
2
3
Not used
-
Not used
-
Not used
-
Description
Disabled.
Outputs from the SO1
(CN1-25, 26) output
terminal
Outputs from the SO2
(CN1-27, 28) output
terminal
Outputs from the SO3
(CN1-29, 30) output
terminal
-
-
-
Parameter Reference
Default
Setting
0:disable
0
0
0
231