Set_Zero_Position - YASKAWA XTRAWARE - V3.0 Manual

Supporting xtradrive versions 3.04 - 3.23
Table of Contents

Advertisement

Command Reference

SET_ZERO_POSITION

Table explanation
Group
Home
Syntax
SET_ZERO_POSITION <mode>
Op. Code
95
Modes
Program, Immediate, Sequential
Description
Zeroes motor position according to <mode>. Actual position: Sets
the actual motor position as zero position. Demand position: Sets
the demand position as zero position (the position error remains).
Syntax
mode
Arguments
Example
LABEL 1
HOME_C 200
GO_D 7800 1000
SET_ZERO_POSITION demand_position
Example
This example shifts the home position (zero position) from the C
Explanation
pulse location to a different location. After searching the C pulse
with the HOME_C command the motor moves to position 7800
UU. When the motor is theoretically on position 7800 UU the scale
is changed and Position_Demand_Value is set to zero.
Position_Actual_Value is Position_Demand_Value plus
Following_Error_actual_Value.
Notes
If error 9 ("Wrong motion mode for SET_ZERO_POSITION
command. Set STOP_EX command before") occurs, insert a
STOP_EX command before the SET_ZERO_POSITION command.
See Also
HARD_HOME, HOME_SW, HOME_SW_C, HOME_C
152
Specify the mode:
Mode
Actual position: Sets the actual
motor position as zero
position.
Demand position: Sets the
demand position as zero
position (The position error will
remain.)
Serial
1
U
Code
0
1
XtraWare User Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xtraware 3.0

Table of Contents