Table 25: Output Signal Selections - YASKAWA XTRAWARE - V3.0 Manual

Supporting xtradrive versions 3.04 - 3.23
Table of Contents

Advertisement

Parameter Reference
8.7.

Table 25: Output Signal Selections

Table 25: Output Signal Selections
Parameter
Digit
Place
Pn50E
0
1
2
3
Pn50F
0
1
2
3
Pn510
0
1
2
3
Note:
Output states can not be monitored in watch window/variables
unless they are assigned as programmable outputs in a
program.
230
Name
Setting
/COIN Signal
0
Mapping
1
2
3
/V-CMP Signal
0 to 3
Mapping
/TGON Signal
0 to 3
Mapping
/S-RDY Signal
0 to 3
Mapping
/CLT Signal
0 to 3
Mapping
/VLT Signal
0 to 3
Mapping
/BK Signal
0 to 3
Mapping
/WARN Signal
0 to 3
Mapping
/NEAR Signal
0 to 3
Mapping
Reserved
0 to 3
Not used
0
Not used
0
Description
Disabled
Outputs from the SO1
(CN1-25, 26) output
terminal
Outputs from the SO2
(CN1-27, 28) output
terminal
Outputs from the SO3
(CN1-29, 30) output
terminal
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
Same as above
-
-
XtraWare User Manual
Default
Setting
0:Disabled
0:Disabled
0:Disabled
0:Disabled
0: Not used
0
0