Simrad SN90 Reference Manual
This illustration shows a
typical matrix presentation.
This is a generic illustration.
Any similarities with specific
products are accidental.
Description
When you move the cursor
over the matrix presentation
of the transceiver channels,
each element in the transducer
can be clearly identified as
a rectangle. If you place the
cursor on top of one of these
rectangles, a small yellow
tool-tip will identify key
information. This function is
designed to check the operation
of the individual channels in
the transceiver, as well as the elements in the transducer.
• The identification of the transducer element
• The identification of the transceiver board
• The measured echo value (in dB)
Tip
A rectangle with 32 black elements in the matrix view indicates a failure with a single
transceiver board. The tooltip will indicate which board that fails. Restarting the SN90
system will normally fix the problem.
Failure of a number of consecutive transceiver boards indicates a problem with the
power supply.
• Weak signals indicate a problem with the supply power to the analogue amplifiers.
• No response indicate a problem with the supply power to the digital circuitry.
• A failure in the high voltage power supply to the transmitter circuitry can only be
detected in the transmit test.
Details
Mode
Select the operating mode of the diagnostic system.