Kongsberg Simrad SN90 Reference Manual page 265

Purse seine and trawling sonar
Hide thumbs Also See for Simrad SN90:
Table of Contents

Advertisement

c
Read the noise value from the noise circle.
d
Record the values in the result table.
e
Repeat for every 2 kHz up to and including the highest test frequency: 120 kHz
1
Increase the operating frequency with 2 KHz.
2
Read the noise value from the noise circle.
3
Record the values in the result table.
f
Ask the bridge to set the next speed.
6
When all the measurements have been made, type the data (speed and noise) into a
spreadsheet to create the curve.
7
Finish the test.
a
Close the
Diagnostics
b
If applicable: Hoist the transducer back up to its upper position.
Result
Speed
0
2
4
6
8
10
12
14
16
381294/E
dialog box.
Speed/Frequency/Noise
Frequency
Maintenance procedures
Noise level
263