11 | Maintenance and troubleshooting
NOTE
Refer to our service and guarantee conditions on our homepage.
ü The cleaning intervals must be adapted to match the ambient conditions of the installation location.
1. In sandy environments, we recommend cleaning the heat sinks and fans every quarter.
↻ Cleaning the heat sink requires the fan to be removed.
↻ Switch off the device and secure it against restart.
↻ Keep a suitable brush ready for cleaning.
1. Remove the hood and fan [See section 11.3} Page 102].
2. Clean the free space between the cover and the heat sink using suitable
brushes.
3. Clean the heat sink with a suitable brush.
. NOTE: Do not use any aggressive cleaning agents and ensure that no
other components come into contact with fluids.
ð Cleaning completed – if necessary, remount the fans.
11.3

Replacing the fans

Removing the cover
↻ It has been ensured that there is no AC/DC voltage present
1. Remove the fastening screws on the cover from both sides [ _T20]
2. Lift up the cover from both sides and press it out of the mounting clips.
3. Set the cover to one side.
ð Proceed with the cleaning or removal of the fans.
Page 102
KACO blueplanet 92.0 TL3 US KACO blueplanet 110 TL3 US KACO blueplanet 125 TL3 US
Manual
3x
2 mm
2
Fig. 103: Cleaning the cooling fins
from above
4x
2
Fig. 104: Cleaning the cooling fins
from below
1 Heat sinks / space between
heat sinks
2 Brush (max. wire diameter
2mm)
3
2
Fig. 105: Removing the cover
1 Cover
2 Fastening screw
3 Mounting clips
4 Fans
1
1
1